User Manual 3155
Programming Reference 4-25
APPLy:SINusoid{<freq>,<ampl>,<offs>,<phase>}
Purpose
This command is a high-level command that programs the 3155 to output sine waveform along with its asso-
ciated parameters
<freq> sets the output frequency in units of Hertz
<ampl> sets the output amplitude in units of Volts
<offs> sets the output offset in units of Volts
<phase> sets the output start phase in units of degrees
Parameter type
Numeric
Parameter range
<freq> 100e-6 to 50e6
<ampl> 80e-3 to 8
<offs> -3.6 to +3.6
<phase> 0 to 360
APPLy:SINusoid?
Response
The 3155 returns <freq>, <ampl>,<offs>,<phase>. Default values are 1e6,5,0,0
APPLy:TRIangle{<freq>,<ampl>,<offs>,<phase>}
Purpose
This command is a high-level command that programs the 3155 to output triangular waveform along with its
associated parameters
<freq> sets the output frequency in units of Hertz
<ampl> sets the output amplitude in units of Volts
<offs> sets the output offset in units of Volts
<phase> sets the output start phase in units of degrees
Parameter type
Numeric
Parameter range
<freq> 100e-6 to 50e6
<ampl> 80e-3 to 8
<offs> -3.6 to +3.6
<phase> 0 to 360
APPLy:TRIangle?
Response
The 3155 returns <freq>, <ampl>,<offs>,<phase>. Default values are 1e6,5,0,0
APPLy:SQUare{<freq>,<ampl>,<offs>,<duty_cycle>}
Purpose
This command is a high-level command that programs the 3155 to output square waveform along with its
associated parameters