Racal Instruments 3155 Spezifikationen Seite 78

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 204
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 77
User Manual 3155
ArbConnection 3-25
Slope – The Slope sub-group selects the edge sensitivity of the trig-
ger input of the 3155. If you click on Positive, the instrument triggers
on the rising edge of the trigger signal. Likewise, if you click on
Negative, the instrument triggers on the falling edge of the trigger
signal.
There are three additional buttons at the right top corner of the
Modulation Panel. You can close the Modulation Panel by clicking on
the Close key, or return to the main panel and leave the Modulation
Panel in the background if you click on the “To Main Panel” key. The
“To FM Composer” button invokes the FM composer program ena-
bling you to create and edit user-defined Frequency Modulation
waveforms which are active when the FM Shape is set to Arb. The
FM Composer program is described in greater detail later in this
chapter.
The Utility Panel
The Utility panel, as shown in Figure 3-9, is invoked either by press-
ing the UTIL button 9on the Panels toolbar) or the “To Utility Panel”
button on the Main Panel. The Utility panel provides access to gen-
eral instrument controls not directly related to waveform generation.
Through this panel you can control multiple instruments and multiple
channels. If you made programming errors, you can also use this
panel to clear the error queue, or to reset the 3155. The functional
groups in the Utility Panel are described below.
Multi-Instrument
Sy
n
chronization
Control
The Multi-Instrument Sync Control group lets you synchronize be-
tween multiple instruments and program phase offsets between in-
struments. A phase offset is applied between the leading edges of
the waveforms from two instruments and is in units of waveform
points. To adjust the Ph. Offset parameter, click on the button below
the parameter. When selected the LED next to the Ph. Offset turns
on. The offset value is displayed on the digital display. Use the dial,
keyboard, or the [
] [
} keys to adjust to the desired setting. After you
modify the reading, press Execute to update the 3155 with the new
reading.
Set Configuration – This lets you select between Master and Slave
modes. Refer to the Synchronizing Multiple Instruments section in
Chapter 4 to find out more about multi-instruments synchronization.
Activate and Deactivate – The buttons turn the coupled mode on
and off.
There are two additional buttons at the right top corner of the Utility
Panel. You can close the Utility Panel by clicking on the Close key, or
return to the main panel and leave the Utility Panel in the background
by clicking on the “To Main Panel” key.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Seitenansicht 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 203 204

Kommentare zu diesen Handbüchern

Keine Kommentare