User Manual 3155
Specifications A-5
Mixed Sequence Advance Each step of a sequence can be programmed to advance
either a) automatically (Automatic Sequence Advance), or b)
with a trigger (Stepped Sequence Advance).
Advance Source External, Internal, or soft trigger
Sequencer steps From 1 to 4096
Segment loops From 1 to 128 K
OUTPUTS
Waveform Output
Connector Front panel BNC
Stand-by (Output Disconnected) Output Off or Normal
Impedance 50Ω, ±1%
Protection Protected against temporary short to case ground
Amplitude
Range 80 mV to 8 Vp-p, into 50Ω; Double into open circuit
Resolution 3.5 digits
Accuracy (1 KHz)
800 mV to 8 Vp-p ±(1% + 10 mV)
80 mV to 799.9 mVp-p ±(1% + 1 mV)
Offset
Offset Offset is attenuated with amplitude
Range 0 to ±3.6 V, amplitude dependent
Resolution 22 mV
Accuracy
±4 V window ±(1% of reading + 1% of amplitude + 2 mV)
±400 mV window ±(1% of reading + 1% of amplitude + 200 µV)
Filters 25MHz or 50 MHz low pass elliptic filter, 7-pole elliptic
(Selectable)
Square Wave, Pulse
Rise/Fall time <10 ns, 10% to 90% of amplitude
Aberration <5%
SYNC/Marker Output
Description Provides dual functionality. All functions and modes, this
output generates sync pulse, which is synchronous with the
output waveform. In FM and sweep modes only, this output
generates a marker having properties similar to the sync
pulse output.
Connector Front panel BNC
Impedance 50Ω, ±1%
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com