User Manual 3155
Programming Reference 4-46
Parameter type
Discrete
OUTPut:FILTer?
Response and default
The 3155 returns NONE, 25M, 50M, or ALL depending on the type of filter presently connected to the output.
Default value is NONE.
OUTPut:SYNC{OFF|ON|0|1}
Purpose
This command turns the 3155 SYNC output on and off.
• ON or 1 sets the SYNC output on
• OFF or 0 sets the SYNC output off
Parameter type
Discrete
OUTPut:SYNC?
Response and default
The 3155 returns 1 if the SYNC output is on, or 0 if the SYNC output is off. Default value is 0.
OUTPut:SYNC:SOURce{BIT|LCOMplete}
Purpose
This command selects the 3155 SYNC option.
• BIT sets the SYNC to output a narrow pulse
• LCOMplete sets the SYNC to transition high at the beginning of the sequence and low a the end of the
sequence
Parameter type
Discrete
OUTPut:SYNC:SOURce?
Response and default
The 3155 returns BIT, or LCOM depending on the present setting of the SYNC source. Default value is BIT.
OUTPut:SYNC:POSition<position>
Purpose
This command programs the 3155 SYNC position. This command is active in arbitrary (USER) mode only.
• <position> sets the SYNC position in waveform points
Parameter type
Numeric (integer only)
Parameter range
<position> 0 to “n” in units of waveform points, where “n” is the size of the active segment. The sync
position is programmed in increments of 4 points minimum.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com