User Manual 3155
Programming Reference 4-44
SINC:NCYCle?
Response and default
The 3155 returns the present number of zero-crossing value. Default value is 10.
GAUSsian:EXPonent<exp>
Purpose
This command programs the exponent for the standard gaussian pulse waveform. This command has no
affect on arbitrary waveforms.
• <exp > sets the exponent parameter
Parameter type
Numeric
Parameter range
<exp> 10 to 200
GAUSsian:EXPonent?
Response and default
The 3155 returns the present exponent value. Default value is 20.
EXPonential:EXPonent<exp>
Purpose
This command programs the exponent for the standard exponential waveform. This command has no affect
on arbitrary waveforms.
• <exp > sets the exponent parameter
Parameter type
Numeric
Parameter range
<exp> -20 to 20
EXPonential:EXPonent?
Response and default
The 3155 returns the present exponent value. Default value is 1.
DC<%_amplitude>
Purpose
This command programs the amplitude of the standard DC waveform. This command has no affect on arbi-
trary waveforms.
• <%_amplitude > sets the dc level as percentage of the programmed amplitude setting
Parameter type
Numeric
Parameter range
<%_amplitude> -100 to 100 in units of percent
DC?
Response and default
The 3155 returns the present dc value. Default value is 100.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Kommentare zu diesen Handbüchern