Racal Instruments 3155 Spezifikationen Seite 155

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 204
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 154
User Manual 3155
Programming Reference 4-44
SINC:NCYCle?
Response and default
The 3155 returns the present number of zero-crossing value. Default value is 10.
GAUSsian:EXPonent<exp>
Purpose
This command programs the exponent for the standard gaussian pulse waveform. This command has no
affect on arbitrary waveforms.
<exp > sets the exponent parameter
Parameter type
Numeric
Parameter range
<exp> 10 to 200
GAUSsian:EXPonent?
Response and default
The 3155 returns the present exponent value. Default value is 20.
EXPonential:EXPonent<exp>
Purpose
This command programs the exponent for the standard exponential waveform. This command has no affect
on arbitrary waveforms.
<exp > sets the exponent parameter
Parameter type
Numeric
Parameter range
<exp> -20 to 20
EXPonential:EXPonent?
Response and default
The 3155 returns the present exponent value. Default value is 1.
DC<%_amplitude>
Purpose
This command programs the amplitude of the standard DC waveform. This command has no affect on arbi-
trary waveforms.
<%_amplitude > sets the dc level as percentage of the programmed amplitude setting
Parameter type
Numeric
Parameter range
<%_amplitude> -100 to 100 in units of percent
DC?
Response and default
The 3155 returns the present dc value. Default value is 100.